You can call a professional or try to do it yourself.
Air conditioning unit in attic leaking water.
Call us to set up a service call and we will stop the leak before it gets larger.
Doing this every few months will kill any.
Low refrigerant could be the sign of a refrigerant leak in your hvac unit.
When the coil melts water overflows the drain pan.
The air conditioner isn t cooling well.
Locate the pvc pipe near your air handler s drain pan.
Why water forms in a central air conditioner indoor unit part of your air conditioner s job is to pull humidity from the air.
When your air conditioner is humming along and cooling your home on a muggy summer day in central ohio you may see water leaking around the unit inside your home.
Then make sure it does not happen again.
If you already have water leaking from your ceiling call a professional air conditioning repair technician immediately to flush out your condensate drain line or replace the drain pan.
Have drain pan shutoff switch installed and equip it with a float.
This humidity is left behind in the form of condensation on the coils.
You hear a hissing or bubbling noise indicating a refrigerant leak depending on the severity of the refrigerant leak you ll either repair the leak or replace the whole ac unit.
The following tips can be used for reducing the chances of water damages.
You ll notice you re low on refrigerant when.
A low refrigerant level can also cause your unit to freeze.
The drain pipe is clogged a clogged drain pipe is the most common cause of standing water in the drain pan.
It should have a piece of pipe sticking up at a 90 degree angle.
Ensure ac unit is installed with a safety pan to catch overflow.
As air passes over the evaporator coils in your air conditioner it cools down and loses some of its humidity.
What should i do if the ac unit in the attic is leaking water.
Unscrew the cap and pour about six ounces of vinegar down the drain line.
Get an annual air conditioning tune up this annual service should be performed by a professional that can check for problems such as clogs in your condensate drain line.
The inside unit s blower pulls in hot humid air through the return grille and over the inside unit s cold evaporator coil pictured above to cool the air down.
And like stated above a thawing unit can cause leaking water.
The air handler itself should have a secondary drain pan installed under the air handler in case if the air handler leaks then the secondary drain pan will catch the condensate and take it to another drain.