The two control layers we re concerned about here are.
Air infiltration from attic through ceiling.
Any ceiling vents need to be foamed and sealed where they meet the ceiling.
Look for dirty insulation which is evidence that air is moving through it.
Most of the time houses are insulated with materials that do not stop air leakage.
Additionally the air tightness of the attic construction itself the un intentional air infiltration i e.
During the summer standard ceiling insulation reduces the transfer of heat from the attic to the living space.
The easiest way to find air leaks is with a blower door.
In the day temperatures can get up to 140f in the attic.
A form of un controlled attic ventilation will also have an influence on the moisture balance.
Spray foam also reduces infiltration through the ceiling.
Once this air sealing work is done you may want to add more insulation to your attic floor.
It reduces energy consumption because the temperature in the attic is lower.
Loose connections should be clamped taped and caulked.
Consider swapping out or upgrading any duct work that is not insulated properly.
During the summer standard ceiling insulation reduces the transfer of heat from the attic to the living space.
Where walls inner and outer meet the attic floor dropped soffits dropped ceiling areas and behind or under attic kneewalls.
Then there are the control layers meant to control the flow of heat air and moisture across the building envelope.
This is building science 101.
Because the pipe gets hot building codes usually require 1 inch of clearance from metal lues 2 inches from masonry chimneys to any combustible material including insulation.
Spray foam also reduces infiltration through the ceiling.
In the day temperatures can get up to 140f in the attic.
The opening around a furnace or water heater lue or chimney can be a major source of warm air moving in the attic.
If you want to add insulation remember that air leaks have to be sealed first.
It reduces energy consumption because the temperature in the attic is lower.
Gently squeeze the trigger and slowly pump foam into the gap.
As long as the roof isn t leaking the biggest wintertime source of attic moisture is air infiltration from the conditioned space through the attic floor air sealing the house at the attic floor basement band joist can do a lot for reducing 24 365 outdoor air infiltration which is the major driver of summertime indoor humidity levels.
If you have an attic ac unit you should take this opportunity to check the air seals on the duct work.
One source is from outdoors through the attic ventilation and the other is from indoors through air leakage across the ceiling plane.
Fill ceiling box gaps with fire blocking foam invert the spray foam can and shove the tube up into the gap.